Fluorescence Imaging
NuGenius is a new generation, low cost, integrated imaging system for DNA and protein analysis and gel documentation.
Complete gel documentation workstation
NuGenius is the ultimate in compact gel documentation workstations. Using a choice of UV, blue or white lighting options you can capture and edit images of fluorescent ethidium bromide, SYBR® Safe or GelGreenTM DNA gels and protein gels stained with Coomassie Blue at the workstation. You can even capture stain-free gel images using a NuGenius+ which is specially optimised for this application.
For an entry level system, the NuGenius comes with a ground breaking 5 million pixel CCD camera giving superb pixel resolution and unrivalled sensitivity. NuGenius offers a maximum viewing area of 20 x 24cm which is very large for such a small, compact unit.
NuGenius+ has been designed for stain free applications. NuGenius+ can be automatically set up in seconds to capture great images of TGX Stain-Free™ FastCast™ acrylamide gels, Mini-PROTEAN® and Criterion™ TGX Stain-Free™ precast gels. Utilising this cost-effective system for imaging stain-free gels will save researchers hours of staining preparation time.
Features
Gel imaging at a touch. DNA and protein gel imaging your way!
- Compact workstation
Plenty of bench space for your research - Complete with built-in processor, touch screen and NuGenius software
Easily capture and edit images on screen without a computer - Motor driven zoom lens
Automatic set up for easy image capture - 5m pixel camera
Resolves close bands and detects nanogram amounts - White, UV and blue lighting options
Flexibility to image fluorescent and visibly stained gels - Stain-free imaging capability with the NuGenius+
Capture images of TGX Stain-Free™ FastCast™ acrylamide gels and many more - Complete networking connectivity (optional)
Easily share and store your results - GeneTools software (unlimited copies)
Analyse date on your own computer
Product specifications
NuGenius | NuGenius+ | |
Camera | 5 million pixel | 5 million pixel |
Sensor | 1/2.5 inch | 2/3 inch |
Bit depth | 12/16 bit | 12/16 bit |
Greyscale | 65,536 | 65,536 |
Dynamic range | 3.6/4.8 (extended) | 3.6/4.8 (extended) |
Lens | 8 – 48mm f/1.2 | 11.5 – 69mm f/1.4 |
Viewing area | 20 x 24cm | 20 x 24cm |
Illumination | ||
Slim transilluminator 20 x 24cm | Option | Option |
Blue converter screen 21 x 26cm | Option | Option |
Visible light converter | Option | Option |
White epi | Yes | Yes |
7 inch touch screen | ||
Software | ||
Image capture | Yes | Yes |
GeneTools analysis | Yes | Yes |
GeneDirectory | Option | Option |
Printer | ||
P95DW Mitsubishi digital thermal printer | P95DW Mitsubishi digital thermal printer | |
Canon Selphy CP1200 | Canon Selphy CP1200 | |
Paper and ink | K65HM thermal paper, matt | K65HM thermal paper, matt |
K91HG thermal paper. glossy | K914HG thermal paper, glossy | |
Canon KP-1081N | Canon KP-1081N | |
Dimensions | ||
H x W x D cms | 75 x 31 x 45 | 75 x 31 x 45 |
Weight | 20kg | 20kg |
Economical gel documentation – DNA and protein gel imaging your way
Using a compact, InGenuis3 gel documentation system you’re in control. You can image your choice of dyes and stains by choosing UV, blue or white lighting options. The system’s GeneSys software selects the right lighting and filters for you, making it easy to image fluorescent ethidium bromide or SYBR® Safe DNA gels and protein gels stained with Coomassie Blue or silver.
For an economical system, the InGenius3 offers a 3m pixel camera and can produce images with 16 bit image depth. A manual zoom lens and manual filter drawer (includes a UV filter) completes the package.
The system is controlled by GeneSys application driven image capture software and comes complete with unlimited copies of GeneTools analysis software.
Features
DNA and protein gel imaging your way
- Small footprint
Plenty of bench space for your experiments - 3m pixel camera
Detect nanogram amounts on gels (up to 20cm x 20cm) - Manual zoom
Puts you in control of the camera - White, UV and blue lighting options
Flexibility to image fluorescent DNA and visibly stained protein gels - High resolution
InGenius3 uses a high resolution 3m pixel camera with a 16 bit image output - Manual system
Allows the user to select filters using a filter drawer, control lighting and the camera lens - GeneSys application driven image capture software
Contains extensive database of dyes and imaging protocols. All you need to know is the type of gel you’re using and GeneSys automatically selects the optimal lighting and filters to produce the perfect image - GeneTools analysis software (unlimited copies)
Analyse data at your own computer.
Product specifications
Camera | InGenius3 |
Sensor | 1/3 inch |
Resolution | 3 million pixels |
Image depth | 12/16 bit |
Greyscales | 4,096/65,536 |
Dynamic range | 3.6 – 4.8 |
Lens | Manual zoom 6.5 – 39, F1.4 |
Maximum viewing area | 20 x 20cm |
Illumination | |
Slim UV transilluminator 20 x 20cm – various single wavelengths are available |
Option |
UltraSlim-LED blue light transilluminator 10 x 12cm | Option |
White Epi overhead | Yes |
Converters | |
UV/visible light NovaGlo converter | Option |
Software | |
GeneSys image capture | Yes |
GeneTools image analysis | Yes |
GeneDirectory | Option |
Conversion screen | |
Novaglo | UV to visible |
Size | |
Dimensions (h x d x w) cm | 62 x 37.5 x 40 |